YOUR RESONATOR TURBO BLOWER NEEDS A RECONDITIONING ONCE IN EVERY 12000 OR 24000 HOURS. OUR FACILITY PROVIDES THE BEST REBUILD AND COST EFFECTIVE TURBO BLOWER. WE ALSO PROVIDE OEM STANDARD CONSUMABLE SPARES FOR THE SAME. LEI HAS INSTALLED 30 AND MORE TURBO BLOWERS ON WARRANTY BASIS WHICH IS AN ADDED BENEFIT TO THE CUSTOMER.
Turbo blower is the precise machine, featuring super high-speed rotation of 60,000 rpm. During laser oscillation, the laser gas pressure is 100 to 110 Torr (1330 to 15000 Pa). The turbo blower circulates this rough–vacuum gas at high speed (up to 200m/s within the discharge tubes) without contaminating the gas. Turbo blower needs a reconditioning or replacement once in a every 12000 or 24000 hours based on the model of OSCILLATOR or RESONATOR.
The turbo blower is not designed to withstand pressurization. So, whenever possible, do not perform a leakage check by pressurizing the turbo blower. Even when internal pressurization is inevitable, never apply a pressure more than 0.08 MPa. Otherwise, components such as connectors or the oil gauge may be damaged. To minimize the risk of connector damage, connect all cables to the turbo blower when applying pressure.
Change turbo blower oil every 4000 hours or 2 years at least. When the quality of the turbo blower oil is deteriorated with long time running, it is possible that the turbo blower breaks down. So please make sure to change the oil with provided hours or less.
There is the laser maintenance screen to manage the periodic maintenance. So please use this function. When the turbo blower is replaced, the gas flow system is open to the atmosphere for a long time. Pay attention to the surrounding environment to ensure that dust and other contaminants do not enter the gas flow system. Do not tilt the turbo blower while transporting and installing it. If the turbo blower is tilted, the oil might enter the gas flow part of it and contaminate the laser gas flow system and optical mirrors, so the tilted turbo blower cannot be used.
This precise machine needs a highly trained professionals to handle it. LASER EXPERTS INDIA provides the best rebuild and cost-effective Turbo blowers along with all the above-mentioned maintenance activities. With the help of diligent and adept professionals, LEI has installed more than 30 turbo blowers throughout India and Middle East countries. We are providing Warranty for all our refurbished Turbo blowers all around the world.
A04B-0800-C017,C009 | C1000E, C1000i-C |
A04B-0800-C019, C011 | C2000E, C2000iB, C2000i-C |
A04B-0800-C025,C015 | C4000E,C4000iB,C4000i-C, C6000i-C |
If the oscillator is not stopped with the correct procedure, the pressure in the vacuum chamber in the oscillator becomes lower than atmosphere. Opening the oil inlet under such a condition lets air enter the turbo blower. This flow of gas causes oil mist to enter the vacuum chamber of the oscillator, resulting in contamination of internal mirrors.
If you do not conduct “Support function for start-up after turbo oil exchange “after replacing the turbo blower oil, abnormal discharge may occur, which can become a cause of the trouble.
To avoid such kind of troubles always contact LASER EXPERTS INDIA professionals to assist you to carry out your Laser cutting machine maintenance